OPC UA

The OPC UA integration runs in process inside cms-api (the node-opcua library, pure JavaScript) — no native SDK and no separate microservice, unlike SAP.

Connection

Register an OPC UA server under External Connections: endpoint, security policy and credentials. Test the connection before configuring the collection.

Collection — OPC_UA_TRIGGER

CMS watches a trigger tag and fires when its value changes. It is event-driven: there is no scheduled polling.

Typical use: the PLC writes 1 to an “order ready” tag; CMS detects it, reads the associated data tags and forwards the message to the ERP.

Browsing tags on the server

Typing the NodeId by hand is where most mistakes happen — and the error only shows up later, when the Collection comes up “connected” and never receives anything. That is why the tag fields have the Browse tags on the OPC UA server popup, which reads the address space of the External Connection’s own server:

WhereHow it opensWhat it does
Collection: Read TagsBrowse server button, next to Add tagTick several tags and add them at once
Delivery: Write TagsBrowse server buttonSame
Collection: Trigger NodeIdMagnifying glass next to the fieldSingle choice: one click on the tag fills the field
Delivery: Trigger NodeId (Permission), of the gateMagnifying glass next to the fieldSingle choice

Browsing starts at Objects and goes down one folder at a time, with the path at the top to go back. At each level the server’s folders and tags appear first and, last, the nodes of the OPC UA standard itself (Server and the like). Each tag shows its DataType (Double, Int32, Boolean…), which helps check whether the trigger value or the value to write matches it.

  • The alias of each added tag is suggested from the display name, already in a format that works in {{alias}} and in JSON. Adjust it afterwards, in the list itself.
  • A tag that is already in the list shows as already in list and is not added twice.
  • A level with more than 1,000 items is cut off, with a warning: use Filter this level.

The popup only appears for those with access to the External Connections screen, and only when the Application has an OPC UA External Connection. Browsing runs in the engine (the worker), the same process that keeps the trigger subscription: it reaches what the Collection will reach — the plant network and the OPC UA server of the Simulators. Each level opens a short session and closes it right after; nothing is left hanging on the server.

Delivery — OPC_UA_WRITE

Writes values to OPC UA server tags from the message data — the path from the ERP back to the shop floor.

Writing changes the state of real equipment. Delivery goes through the write permission gate — keep it enabled in production. With the gate configured and its connection down, the write is refused, not released.

Testing without a PLC

The Simulators screen ships a built-in OPC UA server, with named tag profiles (one per simulated PLC). You can validate triggers and writes end to end before having access to the equipment.

A dropped connection raises the CONEXAO_OPCUA_PERDIDA alert.